Product
AvCount Lube Particle Counter - SA1900-0
The AvCount Lube particle counter determines particle concentration in oils with a viscosity up to 200 mm2/s. FFKM seals have been fitted to resist aggressive oils.
• Simple operation
• Ideal for handling lubricating and hydraulic oils
• 3 minute test time
• Programmable via PC
With a simple test procedure and user friendly features, operator skill or expertise is kept to a minimum.
AvCount Lube can hold up to 3 test methods with custom methods created on a PC before being uploaded using the supplied ProTrend control and analysis software.
Test progress and results for up to 6 size bands are displayed as cumulative particles/ml and ISO 4406, NAS 1638, AS4059 cleanliness codes.
Supplied with: sample probe, waste pipe, universal voltage power supplies, USB cable, calibration certificate and USB memory stick containing handbooks and ProTrend software for test method programming and data download.
Features
- Calibrated to ISO 11171, traceable to NIST SRM 2806d
- Supplied with ASTM D7647, ISO 60970 and ISO 4406 loaded as standard
- FFKM seals compatible with synthetic oils
- Suitable for fluids up to 200mm2/s viscosity
- Precise and reliable results
- Ultra compact rugged, steel case suitable for portable use
- Data storage for up to 600 measurements
- Internal Double Pump System
- USB connection for PC connectivity
Information
Details
Integral CompressorAvCount Lube comprises a light extinction automatic particle counter and a sample delivery unit. Designed to handle samples with a viscosity up to 200 mm2/s, the AvCount Lube has an integral compressor that pressurises the sample chamber to 3 bar.
Calibration and verification:
AvCount Lite utilises 16 point calibration. Calibration can be carried out either using NIST traceable standard solutions or by interfacing with a primary calibrated ‘Master’ AvCount Lite. Calibration can be carried out at a user site or at our authorised regional laboratories. Seta authorised training is required to perform a calibration. Verification can be performed using AvCount Verification Material.
ProTrend (SA1810-0) is supplied with the instrument and can report results to ISO 4406, NAS 1638 and SAE AS4059 (tables 1 and 2) cleanliness codes. Using the software, you can program other test methods and cleanliness codes with up to 16 size bands.
Details
IP 565 | Determination of the level of cleanliness of aviation turbine fuels – portable automatic particle counter method |
---|---|
ASTM D7619 | Method for counting and sizing particles in light and middle distillate fuels, and liquid bio fuels, by automatic particle counter |
GJB 420-1987/420-A-1996/420B-2006 | Fluids contamination testing |
ASTM D7647 | Standard test method for automatic particle counting of lubricating and hydraulic fluids using dilution techniques to eliminate the contribution of water and interfering soft particles by lght extinction |
ISO 60970 | Insulating liquids - Methods for counting and sizing particles |
ISO 11500 | Hydraulic fluid power - Determination of the particulate contamination level of a liquid sample by automatic particle counting using the light-extinction principle |
ISO 4406 | Hydraulic fluid power - Fluids - Method for coding the level of contamination by solid particles |
IEC 60970 | Insulating Liquids, Methods for Counting and Sizing Particles |
JIS B 9932:2012 | Calibration method of automatic particle counter for hydraulic pressure-liquid |
JIS B 9933:2021 | Hydraulic-solid particle contamination degree code display |
JIS B 9934:2012 | By automatic particle counting method using hydraulic pressure-light shielding principle Cleanliness measurement method |
ASTM D6876 | Standard Test Method for Particle Count in Mineral Insulating Oil using Automatic Optical Particle Counters |
Details
Particle Size Range | ISO 11171: 4µm(b) to >70µm(b) |
---|---|
Number of Measuring Channels | 15 when connected to a PC, 6 when used as a stand-alone |
Counts Per Measurement (Max) | 50000/ml |
Sample Viscosity (Max) | 200 mm2/s |
Sample Temperature Range | 0 to 70 °C |
Results | 600 internal, unlimited on PC |
Pump Volume & Flow Rate | 10 ml aliquots @ 30 ml/min or timed |
Total Sample Volume Used (typ) | 80 ml (includes rinse cycles) for ASTM D7647, 20 ml other methods |
Voltage | Automatic particle counter: 12 Vdc, 2.5A (mains adaptor supplied 100 to 240 Vac, 50/60 Hz, 650mA) Pressure delivery unit: 24 Vdc, 2A (mains adaptor supplied 100 to 240 Vac, 50/60 Hz, 1A) |
Size (HxWxD) | 50 x 32 x 28 cm |
Weight | 16 kg |
CCCN Code | Tariff 90318020 |
Methods
Industries
Spares and accessories for AvCount Lube Particle Counter - SA1900-0
Download product profile
To view our full range of products, download our latest Product Profile here.
![Product profile image](https://stanhopeseta.lfdev.co/wp-content/themes/stanhopeseta/assets/images/product-profile.png)
Want to know more?
View our full range of products, or simply get in contact with us for more information.
![Features equipment](https://stanhopeseta.lfdev.co/wp-content/themes/stanhopeseta/assets/images/global-cta-product@x3.png)