Product
Setaflash Series 3 ActiveCool Flash Point Tester - 33200-3
Setaflash Series 3 ActiveCool provides fast and reliable flash point results and requires minimum operator expertise. It has been designed to rapidly and efficiently carry out Flash / No Flash tests to determine the flash point of liquids and semi-solids in the 10 to 135 °C temperature range.
• Compliance
• Safety
• Product quality
• 2 ml of sample and a result in less than 2 minutes
Designed for precise and accurate tests, barometric pressure is measured by an internal barometer and correction is automatically applied to the test result. Unknown samples can be tested using ramp mode.
Setaflash Series 3 ActiveCool has a very simple user interface with colour digital display and touch screen icons which guide the operator through a straightforward testing process. For easy record keeping the instrument stores 100,000 test results which can be saved and transferred via a USB port.
The versatile range of Setaflash instruments are ideal for use in the laboratory, production line or for portable test applications.
Learn more about flash point testing and which instrument you should be using >
Why flash point autosamplers do not comply with flash point test methods >
Setaflash Series 3 ActiveCool Flash Point Tester - 33200-3
Features
- Flash / No Flash & Ramp modes
- Flash point test in less than 2 minutes
- Small sample size - 2 or 4 ml
- Automatic flash detection
- Automatic barometric correction
- Electronic peltier cooling
- USB port and result storage
- Portable operation
- Simple calibration
Information
Details
Rapid Results in just 1 or 2 MinutesThe Setaflash Series 3 ActiveCool is an easy to use instrument that can complete a flash/no flash test in less than two minutes and in many cases in 60 seconds, or determine the flash point of a sample within a temperature range of 0 °C to 135 °C. The sample cup is heated / cooled by peltier cells. This gives very accurate and stable sub-ambient test temperatures and the benefit of rapid temperature normalisation between tests.
Ease of Operation
All functions on the Series 3 ActiveCool including test parameters, instrument status and test results are accessed via the touch screen display and push button. An audible prompt is sounded when a flash is achieved. An automatic flash detector reduces the chance of misinterpretation of the test result by the operator and enhances repeatability.
Innovative Design
Gas for the test jet/shutter assembly is supplied from an integral gas tank, which is filled using a standard butane (lighter) refill cartridge. The Series 3 ActiveCool Flash Point Tester is lightweight and suitable for mobile use when operated from the optional 12 volt power supply adaptor.
Supplied with: 2 ml syringe, ignitor, Allen key, mains lead, quick start guide and instruction manual.
Details
ASTM D3278 | Standard Test Methods for Flash Point of Liquids by Small Scale Closed-Cup Apparatus - paints, enamels, lacquers, varnishes, and related products |
---|---|
ISO 3680 (Obs) | Methods of test for paints. Tests on liquid paints (excluding chemical tests). Test for flash/no flash (rapid equilibrium method) |
UN Class 3 Non-viscous Flammable Liquids | Small Scale Flash Point Testing |
ASTM E502 | Standard Test Method for Selection and Use of ASTM Standards for the Determination of Flash Point of Chemicals by Closed Cup Methods |
ISO 3679 | Determination of flash point. Rapid equilibrium closed cup method |
EPA 1020 A & B | Setaflash Closed-Cup Method for determining ignitability |
ASTM D3828 | Standard Test Methods for Flash Point by Small Scale Closed Tester |
IP 523 | Determination of flash point. Rapid equilibrium closed cup method |
IP 524 | Methods of test for paints. Tests on liquid paints (excluding chemical tests). Test for flash/no flash (rapid equilibrium method) |
ASTM D7236 | Flash Point by Small Scale Closed Cup Ramp Method |
IP 534 | Flash Point by Small Scale Closed Cup Ramp Method |
ASTM D1655 | Standard Specification for Aviation Turbine Fuels |
DEF STAN 91-091 | Aviaton Fuel Specification |
CLP Regulations EC No 1272/2008 | European Regulation (EC) No 1272/2008 on classification, labelling and packaging of substances and mixtures |
BS EN ISO 3679 & BS 2000-523 | Determination of flash no-flash and flash point. Rapid equilibrium closed cup method |
ASTM D8174 | Standard Test Method for Finite Flash Point Determination of Liquid Wastes by Small-Scale Closed Cup Tester |
SW-846 1020C | Standard Test Methods for Flash Point by Setaflash (Small Scale) Closed-Cup Apparatus |
Details
Temperature Range | 10 to 135 °C |
---|---|
Cup Material | Aluminium or stainless steel insert |
Test Modes | Rapid Equilibrium and Ramp |
Sample Size | 2 ml for flash points up to 100 °C 4 ml for flash points above 100 °C |
Test Duration | 1 minute below 100 °C, 2 minutes above 100 °C, or user determination 1 to 99 minutes |
Ramp Rate | 2 °C/min ramp |
Heating and Cooling System | Peltier Cell |
Power | 200 W (maximum) |
Voltage | 100/240 V, 50/60 Hz |
Gas supply | Laboratory gas, 3 kPa (0.44 psi) maximum pressure or Butane from optional Portable Gas Tank 13667-0 |
Size (HxWxD) | 19.5 cm x 29.5 cm x 14 cm |
Weight | 3 kg |
CCCN Code | Tariff 90268020 |
Methods
Industries
Spares and accessories for Setaflash Series 3 ActiveCool Flash Point Tester - 33200-3
Gas Tank - 30000-206
View accessorySilicone Rubber Tube 4 metres - 13730-005
View accessorySample Well O-ring, Viton (Pack of 5) - 13740-004
View accessorySyringe 4 ml (Small Scale Flash Point Instruments) - 13770-311
View accessoryFlash Detector Assembly - 13740-425
View accessorySyringe 2 ml (Small Scale Flash Point Instruments) - 13740-009
View accessoryDownload product profile
To view our full range of products, download our latest Product Profile here.
Want to know more?
View our full range of products, or simply get in contact with us for more information.