Product

Setaflash Series 3e ActiveCool Flash Point Tester - 33220-0

Methods
ASTM D1655
ASTM D3278
ASTM D3828
ASTM D7236
ASTM D8174
ASTM E502
IP 523
IP 524
IP 534
BS EN ISO 3679 & BS 2000-523
ISO 3680 (Obs)
SW-846 1020C

Setaflash Series 3e ActiveCool provides fast and reliable flash point results and requires minimum operator expertise. It has been designed to rapidly and efficiently carry out Flash / No Flash tests to determine the flash point of liquids and semi-solids in the 10 to 135 °C temperature range.

• Compliance
• Safety
• Product quality
• 2 ml of sample and a result in less than 2 minutes

Designed for precise and accurate tests, barometric pressure is measured by an internal barometer and correction is automatically applied to the test result. Unknown samples can be tested using ramp mode.

Setaflash Series 3 ActiveCool has a very simple user interface with colour digital display and touch screen icons which guide the operator through a straightforward testing process. For easy record keeping the instrument stores test results which can be saved and transferred via a USB port.

The versatile range of Setaflash instruments is ideal for use in the laboratory, production line or for portable test applications.

Learn more about flash point testing and which instrument you should be using >

Why flash point autosamplers do not comply with flash point test methods >

Setaflash Series 3e ActiveCool Flash Point Tester - 33220-0

Features

  • Flash / No Flash & Ramp modes
  • Electric ignitor
  • 10 to 135°C temperature range
  • Flash point test in less than 2 minutes
  • Small sample size (2 or 4ml)
  • Automatic flash detection
  • Electronic peltier cooling
  • Inbuilt touch screen
  • Inbuilt USB port
  • Portable operation
  • °C or °F display

Information

Details

Rapid Results in just 1 or 2 Minutes
The Setaflash Series 3 ActiveCool is an easy to use instrument that can complete a flash/no flash test in less than two minutes and in many cases in 60 seconds, or determine the flash point of a sample within a temperature range of 0 °C to 135 °C. The sample cup is heated / cooled by peltier cells. This gives very accurate and stable sub-ambient test temperatures and the benefit of rapid temperature normalisation between tests.

Ease of Operation
All functions on the Series 3 ActiveCool including test parameters, instrument status and test results are accessed via the touch screen display and push button. An audible prompt is sounded when a flash is achieved. An automatic flash detector reduces the chance of misinterpretation of the test result by the operator and enhances repeatability.

Innovative Design
The Series 3 ActiveCool Flash Point Tester is lightweight and suitable for mobile use when operated from the optional 12 volt power supply adaptor.
Supplied with: 2 ml syringe, Allen key, mains lead, quick start guide and instruction manual.

Details

ASTM D3278 Standard Test Methods for Flash Point of Liquids by Small Scale Closed-Cup Apparatus - paints, enamels, lacquers, varnishes, and related products
ISO 3680 (Obs) Methods of test for paints. Tests on liquid paints (excluding chemical tests). Test for flash/no flash (rapid equilibrium method)
ASTM E502 Standard Test Method for Selection and Use of ASTM Standards for the Determination of Flash Point of Chemicals by Closed Cup Methods
ASTM D3828 Standard Test Methods for Flash Point by Small Scale Closed Tester
IP 523 Determination of flash point. Rapid equilibrium closed cup method
IP 524 Methods of test for paints. Tests on liquid paints (excluding chemical tests). Test for flash/no flash (rapid equilibrium method)
ASTM D7236 Flash Point by Small Scale Closed Cup Ramp Method
IP 534 Flash Point by Small Scale Closed Cup Ramp Method
ASTM D1655 Standard Specification for Aviation Turbine Fuels
BS EN ISO 3679 & BS 2000-523 Determination of flash no-flash and flash point. Rapid equilibrium closed cup method
ASTM D8174 Standard Test Method for Finite Flash Point Determination of Liquid Wastes by Small-Scale Closed Cup Tester
SW-846 1020C Standard Test Methods for Flash Point by Setaflash (Small Scale) Closed-Cup Apparatus

Details

Temperature range10 to 135 °C
Sample cup materialAluminium
Test modesRapid Equilibrium and Ramp
Sample size2 ml for flash points up to 100 °C 4 ml for flash points above 100 °C
Test duration1 minute below 100 °C, 2 minutes above 100 °C, or user determination 1 to 99 minutes
Ramp rate2 °C/min ramp
Heating and cooling systemPeltier Cell
Power200 W (maximum)
Voltage100/240 V, 50/60 Hz
IgnitorElectric
Size (HxWxD)19.5 cm x 29.5 cm x 14 cm
Weight3 kg
CCCN CodeTariff 90268020

Methods

ASTM D1655
ASTM D3278
ASTM D3828
ASTM D7236
ASTM D8174
ASTM E502
IP 523
IP 524
IP 534
BS EN ISO 3679 & BS 2000-523
ISO 3680 (Obs)
SW-846 1020C