Product

Setaflash Series 8 ActiveCool Flash Point Tester - 82100-2

Methods
ASTM D1655
ASTM D3278
ASTM D3828
ASTM D7236
ASTM D8174
ASTM E502
IP 523
IP 534
BS EN ISO 3679 & BS 2000-523
CLP Regulations EC No 1272/2008
EPA 1020 B
ISO 3679
ISO 3680 (Obs)
SW-846 1020C

The Setaflash Series 8 ActiveCool, closed cup flash point tester provides fast and reliable flash point results with a wide temperature range of -30 to 135 °C with no external cooling required.

With the Series 8, a test takes less than 2 minutes using just a 2 or 4 ml sample size. A simple user interface with colour digital display and touchscreen icons guides you through the straightforward testing process. For easy record keeping the instrument stores 100,000 test results which can be saved and transferred via a USB port.

Designed for precise and accurate tests, barometric pressure is measured by an internal barometer and correction is automatically applied to the test result. Unknown samples can be tested using ramp mode.

Please note, 82100-2 is comparable to ASTM D3278, ASTM D7236, IP 524 and IP 534, however to be fully compliant a gas ignition should be used. Please see Setaflash Series 8 Flash Point Tester HighTemp – Gas Ignitor - 82050-0

Learn more about flash point testing and which instrument you should be using >

Why flash point autosamplers do not comply with flash point test methods >

Setaflash Series 8 ActiveCool Flash Point Tester - 82100-2

Features

  • Simple test procedure
  • Compact, rugged design
  • Electric ignition
  • Automated flash detection
  • Ramp mode for unknown samples
  • Automatic barometric pressure correction
  • Peltier heating and cooling
  • Fire detection (alarm and relay)
  • USB port and result storage

Information

Details

Ease of use:
All functions on the Series 8 including test parameters, instrument status and test results are accessed via the touchscreen display. An audible prompt sounds when a flash is achieved and an automatic flash detector enhances repeatability.

Safety:
Peltier cells prevent the instrument from overheating, whilst a fire sensor immediately stops the test and cools the sample cup if a fire is detected.

Calibration and verification:
Calibration of the Series 8 can be performed in the field, eliminating the costs and time associated with sending the instrument to a service centre.

Service and maintenance:
The rugged design ensures minimal operational maintenance is needed.

Supplied with: 2 ml syringe, Allen keys, 99878-3 CRM, mains lead and instruction manual.

Details

ASTM D3278 Standard Test Methods for Flash Point of Liquids by Small Scale Closed-Cup Apparatus - paints, enamels, lacquers, varnishes, and related products
ISO 3680 (Obs) Methods of test for paints. Tests on liquid paints (excluding chemical tests). Test for flash/no flash (rapid equilibrium method)
ASTM E502 Standard Test Method for Selection and Use of ASTM Standards for the Determination of Flash Point of Chemicals by Closed Cup Methods
ISO 3679 Determination of flash point. Rapid equilibrium closed cup method
ASTM D3828 Standard Test Methods for Flash Point by Small Scale Closed Tester
IP 523 Determination of flash point. Rapid equilibrium closed cup method
ASTM D7236 Flash Point by Small Scale Closed Cup Ramp Method
IP 534 Flash Point by Small Scale Closed Cup Ramp Method
ASTM D1655 Standard Specification for Aviation Turbine Fuels
CLP Regulations EC No 1272/2008 European Regulation (EC) No 1272/2008 on classification, labelling and packaging of substances and mixtures
BS EN ISO 3679 & BS 2000-523 Determination of flash no-flash and flash point. Rapid equilibrium closed cup method
ASTM D8174 Standard Test Method for Finite Flash Point Determination of Liquid Wastes by Small-Scale Closed Cup Tester
EPA 1020 B Standard test methods for flash point by Setaflash (small-scale) Closed-Cup apparatus
SW-846 1020C Standard Test Methods for Flash Point by Setaflash (Small Scale) Closed-Cup Apparatus

Details

Temperature range-30 to 135 °C
Temperature selection°C or °F
IgnitorElectric
Heating/cooling methodPeltier cell
Temperature ramp modeAutomatic or custom settings (ramp rate up to 10 °C/min)
Sample cup materialAluminium
Pressure correctionAutomatic
Data storage1 GB
Voltage110 to 250 Vac, 50/60 Hz
Size (HxWxD)30 cm x 34 cm x 38 cm
Weight8 kg
CCCN CodeTariff 90268020

Methods

ASTM D1655
ASTM D3278
ASTM D3828
ASTM D7236
ASTM D8174
ASTM E502
IP 523
IP 534
BS EN ISO 3679 & BS 2000-523
CLP Regulations EC No 1272/2008
EPA 1020 B
ISO 3679
ISO 3680 (Obs)
SW-846 1020C

Download product profile

To view our full range of products, download our latest Product Profile here.

Product profile image

Want to know more?

View our full range of products, or simply get in contact with us for more information.

Features equipment